Dear Joaquin Juarez, I took a look at the document you give. I think you can make the system as your description: PLC <---Ethernet/IP---> CSE-M53N There are two ways to do it: 1. Configure your PLC as TCP server , CSE-M53 as TCP Client 2. Configure your PLC as TCP client , CSE-M53 as TCP server You can configure CSE-M53 to work as TCP client or server using ezManager software. Please refer to page 15 to 17 of User Manual: https://www.eztcp.com/en/download/pds_files/an_ezmanager_en.pdf On PLC side, you should find how to configure on PLC'ss User Manual or contact to PLC'ss provider. If you have any further question, please feel free to contact us Best regards, > Joaquin Juarez wrote: > ------------------------------------ > Hello, > > The PLC is a AB 1756-L72S. But the communication is done thorugh a netword card 1756-EN2T. > > Following is the documentation for both of them. > > 1756-L72S: > https://literature.rockwellautomation.com/idc/groups/literature/documents/um/1756-um020_-en-p.pdf > > 1756-EN2T: > https://literature.rockwellautomation.com/idc/groups/literature/documents/um/enet-um006_-en-p.pdf > > Hope this helps. > > > Sollae Systems wrote: > > ------------------------------------ > > Dear Joaquin Juarez, > > > > We do not know the specification of your PLC > > > > Does your PLC can connect to LAN networks? > > If have, your PLC should be configured as TCP Server and CSE-M53N should be configured as TCP client , or vice versa. > > > > Could you please send us model name of your PLC or its manual? > > > > > > > Joaquin Juarez wrote: > > > ------------------------------------ > > > Hello, > > > > > > I just want to make sure, would the following work to establish connection with the CSE-M53N: > > > > > > PLC <---Ethernet/IP---> CSE-M53N > > > > > > > > > If yes, woudl you be able to provide an example of how to configure it with a Allen Bradly PLC. > > > > > > If not, then what would be the expected architecture? > > > > > > Please let me know if you have any questions. > > > > > > Best Regards > > > Joaquin > > > > > > > Sollae Systems wrote: > > > > ------------------------------------ > > > > You are welcome! > > > > > > > > If you meet any issue, please feel free to contact us. > > > > > > > > Best regards. > > > > > > > > > > > > > Joaquin Juarez wrote: > > > > > ------------------------------------ > > > > > > > > > > Hello, > > > > > > > > > > Thank you, we will try do just that. > > > > > > > > > > And the current architecture we want to make it work is: > > > > > > > > > > PLC <---Ethernet/IP---> CSE-M53N > > > > > > > > > > Which we suspect is not going to work. > > > > > > > > > > > > > > > > Sollae Systems wrote: > > > > > > ------------------------------------ > > > > > > Dear Joaquin Juarez, > > > > > > > > > > > > Thank you for your information > > > > > > > > > > > > I am not clear about your network architecture. > > > > > > > > > > > > If i am correct, it should be: > > > > > >
PLC
<----Serial----->
CSE-M53N
<-----TCP/IP----->
PC (
----TCP/IP--->
ezVSP
<----Virtual Serial--->
OPC Server )
> > > > > > > > > > > > If so, you need to establish TCP connection between ezVSP and CSE-M53N. > > > > > > Could you please send us the configuration of TCP connection on ezVSP? > > > > > > > > > > > > If possible, we can do a remote support via a remote software, which is similar to TeamViewer. > > > > > > If possible, please contact us via email support@eztcp.com. Our working time is from 9:00AM to 6:00PM (GMT+9) > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > Joaquin Juarez wrote: > > > > > > > ------------------------------------ > > > > > > > > > > > > > > Hello, > > > > > > > > > > > > > > Thank you for your fast response. > > > > > > > > > > > > > > My goal is to see if I can communicate directly to the module using a PLC. > > > > > > > > > > > > > > -Architecture: > > > > > > > Network Card 1756-EN2T (Ethernet/IP) connected to the CSE-M53N (Through a switch). > > > > > > > System does not have a serial port. > > > > > > > > > > > > > > -Find the settings in the attached PDF. > > > > > > > > > > > > > > -I do not use any PC to transfer the data. I would be looking to do it with the PC. > > > > > > > > > > > > > > Now I might be jumping ahead, but in case my approach is wrong, would I need to do something like the following?: > > > > > > > PLC --> PC (Running OPC Server and ezVSP) --> CSE-M53N > > > > > > > > > > > > > > Best regards > > > > > > > Joaquin Juarez > > > > > > > > > > > > > > > Sollae Systems wrote: > > > > > > > > ------------------------------------ > > > > > > > > Hello Joaquin Juarez, > > > > > > > > > > > > > > > > Thank you for using our product. > > > > > > > > > > > > > > > > In order to find out the issue, could you please describe detail about: > > > > > > > > - Your system architecture > > > > > > > > - Setting of Serial Device > > > > > > > > - Setting on CSE-M53 (network and serial setting) > > > > > > > > - Which software do you use on PC to transfer data > > > > > > > > ? > > > > > > > > > > > > > > > > Thank you, > > > > > > > > Best regards, > > > > > > > > > > > > > > > > > > > > > > > > > Joaquin Juarez wrote: > > > > > > > > > ------------------------------------ > > > > > > > > > Hello, > > > > > > > > > > > > > > > > > > I have a Display that makes use of the CSE-M53N, connected to a local network over ethernet. > > > > > > > > > > > > > > > > > > I have not been able to connect the PLC to this communication module. I am wondering if you have any prior example I could use. > > > > > > > > > > > > > > > > > > Best Regards
Password
Attachment
(Image, ZIP file under 2MB)
Notice
Technical Support
FAQ
Q&A
Customer Support
Sales & Quotation
Survey