I would like to correct a small detail as below: SMG-5420 is configured via spFinder software https://www.eztcp.com/en/download/spfinder.php, If there are still any problems, please send us the screenshot of spFinder that shows SMG-5420 status. The screenshot would be similar to the image on page 20 of SMG-5420 User Manual. > Dan Burns wrote: > ------------------------------------ > Regarding the SMG-5420. Can the SMG-5420 be used with the ezVSP? > > I am using Modbus Poll to connect thru the smg-5420 to a modbus rtu rs485 device. This setup works OK when Modbus Poll is connected to the smg-5420 server. > > When I try to use a ezVSP virtual com port, I can not communicate with the modbus device. > > I see that when I use Modbus Poll in Modbus/tcp that the tcp header gets sent with the serial data to the smg-5420 server. With Modbus Poll thru the serial port only the serial data gets sent to the smg-5420 there is no tcp header information. Is there some setting I need for the ezVSP virtual com port to add the tcp header? > > Thanks, Dan