Hello again. To send the data(Modbus/TCP), you should develop the software to control the CIE-H12. We provide sample sources of Modbus/TCP protocol at homepage. And also you can use the Modmap as you know. If you want test with ezManager, [Simple test] program is possible. Please see the attachment. You are able to test like that. Thank you. (Pulse fucntion of HTML is not supported yet. sorry) > geve wrote: > ------------------------------------ > Thanks for your reply. > It is verry helpfull that I now know the ports used by ModBus. I will test it end of the week. > > You example for a 1 second pulse matches my code. What I don not know yet is where to put the code to conduct the CIE H12 by internet (is not a code to put in HTML or in EZmanager). How can I send the code to the CIE H12 or whitch program can I use to send the code ? > > Thanks for your help and time > > Regards, Gerrit > > > Sollae Systems wrote: > > ------------------------------------ > > Hello. > > > > This is a technical support team of Sollae Systems. > > > > First of all, port will be forwared to use the Internet. > > > > If you didn'st change the defalt port numbers, > > please confirm it below to forward. > > > > 1. TCP 502 (for Modbus/TCP) > > 2. UDP 50005 (for searching) > > 3. TCP 80 (for HTTP) > > > > And p.26 of a document for Modbus/TCP protocol shows about Pulse function. > > > > Here is a example of pulse (1 second). > > > > [0x00 0x00 0x00 0x00 0x00 0x07 0x01 0x69 0x00 0x08 0x03 0xe8 0xff] > > > > 0x03 0xe8 means 1 second. > > > > Thank you. > > > > Have a nice day. > > > > > > > > > > > geve wrote: > > > ------------------------------------ > > > Good afternoon, > > > > > > In Modmap I can only see a CIE H12 in the same LAN. When entering the IP & port number from the CIE H12 in internet (by internet browser I can see and switch the output)the CIE H12 can not be found. In the routers (my LAN and the client LAN the CIE H12 port is forwarded (checked with a browser and a port check) > > > Is there a extra port that needs to be forwarded to use Modmap ? > > > > > > I have read the Modbus TCP document but someware miss the way to send this code to the CIE H12. (do I need to make a magic package to send to the CIE H12 in the internet like I use to wake PC'ss on LAN, and where can I find information to make and send this package ?) If this is not the right way, where can I find the information to use Modbus/TCP to send a pulse to the CIE H12 ? > > > > > > Stan, are you willing to share your JAVA code ? > > > > > > Thank you for your attention and tips, regards, Gerrit
Password
New file
(*The above file attachment will be deleted. Image, ZIP file under 2MB)
20120627_h55_pulse.png
Notice
Technical Support
FAQ
Q&A
Customer Support
Sales & Quotation
Survey