한국어
|
English
PRODUCTS
SOLUTIONS
APPLICATIONS
SUPPORT
DOWNLOAD
WHERE TO BUY
ABOUT US
Support
>
Technical Support
Q&A
/ Technical Support
Name
E-mail
Company Name
Subject
Contents
> Anonymous wrote: > ------------------------------------ > Hi Sollae Systems! Thanks for regards! I dont understand know how to send a data from (user device) with rs-232 to Host(web server) thought cse-H53n and after host could response a data to user device. Do you give me something a example to connect it? Thanks so much > Sollae Systems wrote: > ------------------------------------ > Hello. > > If your device has LAN port, you can connect to host directly without CSE-H53N. > > But If you want to use RS232 port, TCP connection is needed between CSE-H53N and host. > > Here are Examples. > > 1. > > [CSE-H53N] > Server > IP address: 192.168.1.2 > Local port: 1470 > > [Host with socket program] > Client > IP address: 192.168.1.3 > Peer IP address: 192.168.1.2 (server IP) > Peer port: 1470 (server port) > > 2. > > [CSE-H53N] > Client > IP address: 192.168.1.2 > Peer IP address: 192.168.1.3 (server IP) > Peer port: 1470 (server port) > > [Host with socket program] > Server > IP address: 192.168.1.3 > Local port: 1470 > > > If TCP connection is established, STS LED of CSE-H53N will be on. > > After that, You can send data from RS232 to LAN and vice versa. > > Thank you. > > > > Anonymous wrote: > > ------------------------------------ > > > > Hello Sollae > > > > Thanks you so much for relay > > > > My device is a network device but only > > two communication port: LAN, RS-232c > > LAN has connect to router > > RS-232c: i use CSE-h53n to connect HOST > > This is my problem and Im trying connect RS-232c to HOST...(T_T) > > > > > > Thanks > > > > > Sollae Systems wrote: > > > ------------------------------------ > > > Hello. > > > > > > CSE-H53N is just a serial to ethernet converter. > > > > > > I am not sure why you use CSE-H53N even if your device is a network device. > > > > > > If the Host sends HTTP protocol, CSE-H53N bypass to RS232 port. > > > > > > Then serial port of your device can receive data. > > > > > > So you should implements about HTTP protocol to send to the host. > > > > > > We do not have any examples. > > > > > > So I am sorry we can not support to get url files. > > > > > > You can find an application note about HTTP protocol at our hompage. > > > > > >
Implementing HTTP
> > > > > > For the detailed information, refer to the RFC2616. > > > > > > I hope It will be helpful. > > > > > > Thank you. > > > > > > > > > > > > > Anonymous wrote: > > > > ------------------------------------ > > > > Hello Sollae! > > > > > > > > I have a example: > > > > My device: > > > > OS: linux > > > > IP: 192.168.1.1 > > > > CSE-H53n: > > > > IP: 192.168.1.2 > > > > TCP Server port is 80 > > > > HOST: > > > > OS: linux > > > > IP: 192.168.1.3 > > > > url get file: http://192.168.1.3/download.pdf > > > > > > > > above My device how to bypass data to call url form host thought CSE-H53n > > > > > > > > Can you give me a example for do that! > > > > > > > > Thanks for regards > > > > > > > > > Sollae Systems wrote: > > > > > ------------------------------------ > > > > > Hello. > > > > > > > > > > This is a technical support team of Sollae Systems. > > > > > > > > > > I think you want to communicate each other through HTTP protocol. > > > > > > > > > > But CSE-H53N(or all of ezTCP) supported only TCP/IP protocol. > > > > > > > > > > HTTP is the Application layer. > > > > > > > > > > CSE-H53N does not care about an application layer. > > > > > > > > > > It just bypass all data from serial device to the host. > > > > > > > > > > So, after TCP connection between CSE-H53N and a host, you can send what you implement protocol to the host and vice versa. > > > > > > > > > > Have a nice day. > > > > > > > > > > Thank you. > > > > > > > > > > > > > > > > > > > > > > > > > > Khanh wrote: > > > > > > ------------------------------------ > > > > > > Current i have a problem with get content html > > > > > > > > > > > > This is my environment > > > > > > > > > > > > Device(supported web server) -> cse-h53n -> HOST(web server) > > > > > > > > > > > > Device connect to cse-h53n by serial rs-232c > > > > > > HOST connect to cse-h53n by LAN > > > > > > > > > > > > Question: I can call a url from Device to HOST thought cse-h53n and get result is html content from HOST? > > > > > > > > > > > > how i can setting on cse-h53n > > > > > > > > > > > > > > > > > > > > > > > > > > > > > >
Password
Security Code
Attachment
(Image, ZIP file under 2MB)
Notice
Technical Support
FAQ
Q&A
Customer Support
Sales & Quotation
Survey