한국어
|
English
PRODUCTS
SOLUTIONS
APPLICATIONS
SUPPORT
DOWNLOAD
WHERE TO BUY
ABOUT US
Support
>
Technical Support
Q&A
/ Technical Support
Name
E-mail
Company Name
Subject
Contents
> Sollae Systems wrote: > ------------------------------------ > Dear Dan Burns, Thank you for using our products. Firstly, ezVSP converts serial data from a serial software on PC to TCP data. You need to configure ezVSP as described in this document https://www.eztcp.com/en/download/pds_files/an_ezvsp_en.pdf. If it still does not work, please send us the screenshot of your ezVSP configuration. Secondly, SMG-5420 CANNOT use with ezVSP. Because SMG-5420 converts Modbus/TCP data to Modbus/RTU (or ASCII) data, and vice versa. Therefore, - Modbus/TCP device/software connects to SMG-5420 via TCP/IP network (Ethenet port) - Modbus/RTU (or ASCII) device/software connects to SMG-5420 via serial port In the case you use Modbus Poll software, You CAN: - connect Modbus Poll (configured as ModbusTCP) to SMG-5420 via TCP/IP network (with TCP header) - connect Modbus Poll (configured as Modbus/RTU) to SMG-5420 via serial port (without TCP header) You CANNOT: - uses Modbus Poll (configured as Modbus/RTU) to SMG-5420 via TCP/IP network (through ezVSP). Because in this case, Modbus/RTU data is sent over TCP/IP, NOT Modbus/TCP. SMG-5420 is configured via spFinder software https://www.eztcp.com/en/download/spfinder.php, If you meet any problem, please send us the screenshot of SMG-5420 status in spFinder. It looks like this image: https://www.eztcp.com/en/download/images/spfinder.png I hope the above is useful to you. Please feel free to contact me if you need any further information. Thank you, Best regards, > Dan Burns wrote: > ------------------------------------ > Regarding the SMG-5420. Can the SMG-5420 be used with the ezVSP? > > I am using Modbus Poll to connect thru the smg-5420 to a modbus rtu rs485 device. This setup works OK when Modbus Poll is connected to the smg-5420 server. > > When I try to use a ezVSP virtual com port, I can not communicate with the modbus device. > > I see that when I use Modbus Poll in Modbus/tcp that the tcp header gets sent with the serial data to the smg-5420 server. With Modbus Poll thru the serial port only the serial data gets sent to the smg-5420 there is no tcp header information. Is there some setting I need for the ezVSP virtual com port to add the tcp header? > > Thanks, Dan
Password
Security Code
Attachment
(Image, ZIP file under 2MB)
Notice
Technical Support
FAQ
Q&A
Customer Support
Sales & Quotation
Survey