No. 1176 | Problem connecting CSW-M85 to existing design | 2013-04-15 | ||
---|---|---|---|---|
Hello! I am trying to use CSW-M85 to an existing system. Everything works fine when I use your Evaluation Board, but I got problem when connecting directly to the module using TTL 3.3V levels. I get data out of CSW-M85, but can't sink data zeroes to CSW-M85 enough to be a valid zero. I think that your module has an internal pull up of about 10K. My existing system has a serial resistance at TX of the same magnitude explaining the problem... Is there any way to disable the internal pull up of CSW-M85? Grateful for any hints! Best regards, Jonas Larby. MSc/Software Consultant. |
Writer | Jonas Larby | Company | Digital Design WW AB |
|
|||