한국어 English Chinese Russian
bannerbar

Q&A



Your information is protected by SSL.
No. 1273 Re: DTR line problem CSE-H25 2014-05-27

Hello. This is Peter Lee at technical support team of Sollae Systems.

The DTR is always high when it boots up because it is always ready.
It can't meet your requirement.

I am very sorry about it.


> Stephane wrote:
> ------------------------------------
> Hello there
>
> I bought a CSE-H25 a few days ago.
>
> I have a problem to control the DTR pin
>
> Checking the box DTR/DSR in ez manager does not have any effect...
>
> After using the ez manager 3.3A beta and checking 'telnet COM port control' i was able to control the DTR pin. The box DTR/DSR is then grey
>
> Unfortunatly when i unplug the CSE-H25, on the next boot it will put the DTR-pin in the HIGH-mode, until i launch my software.
>
> On all the computers i've tested, when the computer boot, the DTR pin will be in low mode.
>
> The DTR pin is used on my device to ctrl the reset line, so when the CSE-h25 is rebooted my device could not work until i start my software.
>
> is there any fix for that? (DTR line in low mode (-12v) when the device is reboot)
>
> Best regards.
>

Writer Sollae Systems Company