No. 1348 Re: Re: Re: Re: Re: How i can get content html thought cse-h53n 2015-07-20

Hello.

If your device has LAN port, you can connect to host directly without CSE-H53N.

But If you want to use RS232 port, TCP connection is needed between CSE-H53N and host.

Here are Examples.

1.

[CSE-H53N]
Server
IP address: 192.168.1.2
Local port: 1470

[Host with socket program]
Client
IP address: 192.168.1.3
Peer IP address: 192.168.1.2 (server IP)
Peer port: 1470 (server port)

2.

[CSE-H53N]
Client
IP address: 192.168.1.2
Peer IP address: 192.168.1.3 (server IP)
Peer port: 1470 (server port)

[Host with socket program]
Server
IP address: 192.168.1.3
Local port: 1470


If TCP connection is established, STS LED of CSE-H53N will be on.

After that, You can send data from RS232 to LAN and vice versa.

Thank you.


> Anonymous wrote:
> ------------------------------------
>
> Hello Sollae
>
> Thanks you so much for relay
>
> My device is a network device but only
> two communication port: LAN, RS-232c
> LAN has connect to router
> RS-232c: i use CSE-h53n to connect HOST
> This is my problem and Im trying connect RS-232c to HOST...(T_T)
>
>
> Thanks
>
> > Sollae Systems wrote:
> > ------------------------------------
> > Hello.
> >
> > CSE-H53N is just a serial to ethernet converter.
> >
> > I am not sure why you use CSE-H53N even if your device is a network device.
> >
> > If the Host sends HTTP protocol, CSE-H53N bypass to RS232 port.
> >
> > Then serial port of your device can receive data.
> >
> > So you should implements about HTTP protocol to send to the host.
> >
> > We do not have any examples.
> >
> > So I am sorry we can not support to get url files.
> >
> > You can find an application note about HTTP protocol at our hompage.
> >
> > Implementing HTTP
> >
> > For the detailed information, refer to the RFC2616.
> >
> > I hope It will be helpful.
> >
> > Thank you.
> >
> >
> >
> > > Anonymous wrote:
> > > ------------------------------------
> > > Hello Sollae!
> > >
> > > I have a example:
> > > My device:
> > > OS: linux
> > > IP: 192.168.1.1
> > > CSE-H53n:
> > > IP: 192.168.1.2
> > > TCP Server port is 80
> > > HOST:
> > > OS: linux
> > > IP: 192.168.1.3
> > > url get file: http://192.168.1.3/download.pdf
> > >
> > > above My device how to bypass data to call url form host thought CSE-H53n
> > >
> > > Can you give me a example for do that!
> > >
> > > Thanks for regards
> > >
> > > > Sollae Systems wrote:
> > > > ------------------------------------
> > > > Hello.
> > > >
> > > > This is a technical support team of Sollae Systems.
> > > >
> > > > I think you want to communicate each other through HTTP protocol.
> > > >
> > > > But CSE-H53N(or all of ezTCP) supported only TCP/IP protocol.
> > > >
> > > > HTTP is the Application layer.
> > > >
> > > > CSE-H53N does not care about an application layer.
> > > >
> > > > It just bypass all data from serial device to the host.
> > > >
> > > > So, after TCP connection between CSE-H53N and a host, you can send what you implement protocol to the host and vice versa.
> > > >
> > > > Have a nice day.
> > > >
> > > > Thank you.
> > > >
> > > >
> > > >
> > > >
> > > > > Khanh wrote:
> > > > > ------------------------------------
> > > > > Current i have a problem with get content html
> > > > >
> > > > > This is my environment
> > > > >
> > > > > Device(supported web server) -> cse-h53n -> HOST(web server)
> > > > >
> > > > > Device connect to cse-h53n by serial rs-232c
> > > > > HOST connect to cse-h53n by LAN
> > > > >
> > > > > Question: I can call a url from Device to HOST thought cse-h53n and get result is html content from HOST?
> > > > >
> > > > > how i can setting on cse-h53n
> > > > >
> > > > >
> > > > >
> > > > >
> > > > >

Writer Sollae Systems Company