No. 1361 | Re: Installing CSW-H85K | 2015-08-03 | ||
---|---|---|---|---|
Hello. If it works only PWR led when you input the power(5V) with RUN mode(switch to center), it is a weird situation. The others must be blink. Please follow these steps below. 1. Change the swith which is back of product to SET mode. 2. Turn CSW-H85K on. (DC5V) 3. 4 LEDs blink.(TXD, TXD, LINK, STS) 4-1. Select COM port, open and read it at Serial tab of ezManager. 4-2. If 4-1 is failed, please use a smart phone. 4-2-1. select wifi cfg_0030f9XXXXXX. 4-2-2. Open Web browser and connect to Http://10.1.0.1 5. Change the evironment variables of CSW-H85K and write it. 6. Change the switch to RUN(center) If test is failed, please let me know which one is a problem. Thank you. > Angelo wrote: > ------------------------------------ > Hello > > I'sm trying to install CSW-H85K in my test environment. After pluggin it to +5V DC I can see only the POWER Led (Red) lit. > > No other led is on, I'sm trying to setting to config mode but cannot get through, no other led is flashing even by pressing the function button switch 5seconds or changing the function switch to SET mode. ezManager does not detect the device attached to com port and we'sre not able to configure it. > > Neither setting to factory defaults is working; it'ss like the device is dead but I see the PWR led switched on. > > What could be the problem > > thanks |
Writer | Sollae Systems | Company | |
|
|||