No. 1425 Re: CSE-H53 baud rate 2016-11-10

Dear Joep,

Thank you for using our products.
The CSE-H53 isn'st support telnet commands for the settings.
You can change the settings of the com port on ezTCP manager.
I think you check an option about Telnet COM Port Control(RFC2217) in Serial Port tab.
If the option is enable you can'st control the settings of the com port.
Please try again after you turn off the option.

Thank you.


> joep wrote:
> ------------------------------------
> I have a CSE-H53 with a Sony beamer connected on the RS-232 port.
> This beamer requires a baud rate of 38.4 kbps with even parity, one stop and one start bit.
> I would like to send a command to the RS-232 port with telnet from a linux machine.
> I can successfully connect to the CSE-H53 with telnet.
> For example 'sst uptime's works fine.
>
> I cannot find any way to set the baud rate and the other settings of the com port.
> I tried ezTCP manager 3.5C on a Windows machine but the options for CPM1 are all greyed out.
>
> Do you have any idea how to do this?
> Thanks,
> Joep

Writer Sollae Systems Company