No. 1426 Re: Re: CSE-H53 baud rate 2016-11-10

Thanks!

Indeed Telnet COM Port Control was turned on.
I'm not in the opportunity to test this until the weekend so I'll post an update after that.

Joep


> Sollae Systems wrote:
> ------------------------------------
> Dear Joep,
>
> Thank you for using our products.
> The CSE-H53 isn'st support telnet commands for the settings.
> You can change the settings of the com port on ezTCP manager.
> I think you check an option about Telnet COM Port Control(RFC2217) in Serial Port tab.
> If the option is enable you can'st control the settings of the com port.
> Please try again after you turn off the option.
>
> Thank you.
>
>
> > joep wrote:
> > ------------------------------------
> > I have a CSE-H53 with a Sony beamer connected on the RS-232 port.
> > This beamer requires a baud rate of 38.4 kbps with even parity, one stop and one start bit.
> > I would like to send a command to the RS-232 port with telnet from a linux machine.
> > I can successfully connect to the CSE-H53 with telnet.
> > For example 'sst uptime's works fine.
> >
> > I cannot find any way to set the baud rate and the other settings of the com port.
> > I tried ezTCP manager 3.5C on a Windows machine but the options for CPM1 are all greyed out.
> >
> > Do you have any idea how to do this?
> > Thanks,
> > Joep