No. 1672 Re: Re: Re: Re: Re: Re: Re: Re: Communication to a CSE-M53N using controllogix PLC 2019-05-21

Hello,

The PLC is a AB 1756-L72S. But the communication is done thorugh a netword card 1756-EN2T.

Following is the documentation for both of them.

1756-L72S:
https://literature.rockwellautomation.com/idc/groups/literature/documents/um/1756-um020_-en-p.pdf

1756-EN2T:
https://literature.rockwellautomation.com/idc/groups/literature/documents/um/enet-um006_-en-p.pdf

Hope this helps.

> Sollae Systems wrote:
> ------------------------------------
> Dear Joaquin Juarez,
>
> We do not know the specification of your PLC
>
> Does your PLC can connect to LAN networks?
> If have, your PLC should be configured as TCP Server and CSE-M53N should be configured as TCP client , or vice versa.
>
> Could you please send us model name of your PLC or its manual?
>
>
> > Joaquin Juarez wrote:
> > ------------------------------------
> > Hello,
> >
> > I just want to make sure, would the following work to establish connection with the CSE-M53N:
> >
> > PLC <---Ethernet/IP---> CSE-M53N
> >
> >
> > If yes, woudl you be able to provide an example of how to configure it with a Allen Bradly PLC.
> >
> > If not, then what would be the expected architecture?
> >
> > Please let me know if you have any questions.
> >
> > Best Regards
> > Joaquin
> >
> > > Sollae Systems wrote:
> > > ------------------------------------
> > > You are welcome!
> > >
> > > If you meet any issue, please feel free to contact us.
> > >
> > > Best regards.
> > >
> > >
> > > > Joaquin Juarez wrote:
> > > > ------------------------------------
> > > >
> > > > Hello,
> > > >
> > > > Thank you, we will try do just that.
> > > >
> > > > And the current architecture we want to make it work is:
> > > >
> > > > PLC <---Ethernet/IP---> CSE-M53N
> > > >
> > > > Which we suspect is not going to work.
> > > >
> > > >
> > > > > Sollae Systems wrote:
> > > > > ------------------------------------
> > > > > Dear Joaquin Juarez,
> > > > >
> > > > > Thank you for your information
> > > > >
> > > > > I am not clear about your network architecture.
> > > > >
> > > > > If i am correct, it should be:
> > > > > PLC <----Serial-----> CSE-M53N <-----TCP/IP-----> PC (----TCP/IP---> ezVSP <----Virtual Serial---> OPC Server )
> > > > >
> > > > > If so, you need to establish TCP connection between ezVSP and CSE-M53N.
> > > > > Could you please send us the configuration of TCP connection on ezVSP?
> > > > >
> > > > > If possible, we can do a remote support via a remote software, which is similar to TeamViewer.
> > > > > If possible, please contact us via email support@eztcp.com. Our working time is from 9:00AM to 6:00PM (GMT+9)
> > > > >
> > > > >
> > > > >
> > > > >
> > > > > > Joaquin Juarez wrote:
> > > > > > ------------------------------------
> > > > > >
> > > > > > Hello,
> > > > > >
> > > > > > Thank you for your fast response.
> > > > > >
> > > > > > My goal is to see if I can communicate directly to the module using a PLC.
> > > > > >
> > > > > > -Architecture:
> > > > > > Network Card 1756-EN2T (Ethernet/IP) connected to the CSE-M53N (Through a switch).
> > > > > > System does not have a serial port.
> > > > > >
> > > > > > -Find the settings in the attached PDF.
> > > > > >
> > > > > > -I do not use any PC to transfer the data. I would be looking to do it with the PC.
> > > > > >
> > > > > > Now I might be jumping ahead, but in case my approach is wrong, would I need to do something like the following?:
> > > > > > PLC --> PC (Running OPC Server and ezVSP) --> CSE-M53N
> > > > > >
> > > > > > Best regards
> > > > > > Joaquin Juarez
> > > > > >
> > > > > > > Sollae Systems wrote:
> > > > > > > ------------------------------------
> > > > > > > Hello Joaquin Juarez,
> > > > > > >
> > > > > > > Thank you for using our product.
> > > > > > >
> > > > > > > In order to find out the issue, could you please describe detail about:
> > > > > > > - Your system architecture
> > > > > > > - Setting of Serial Device
> > > > > > > - Setting on CSE-M53 (network and serial setting)
> > > > > > > - Which software do you use on PC to transfer data
> > > > > > > ?
> > > > > > >
> > > > > > > Thank you,
> > > > > > > Best regards,
> > > > > > >
> > > > > > >
> > > > > > > > Joaquin Juarez wrote:
> > > > > > > > ------------------------------------
> > > > > > > > Hello,
> > > > > > > >
> > > > > > > > I have a Display that makes use of the CSE-M53N, connected to a local network over ethernet.
> > > > > > > >
> > > > > > > > I have not been able to connect the PLC to this communication module. I am wondering if you have any prior example I could use.
> > > > > > > >
> > > > > > > > Best Regards

Writer Joaquin Juarez Company Callisto Integration