No. 1879 | Re: Temperature range for CIE-M10 | 2023-03-20 | ||
---|---|---|---|---|
Dear Phil, Thank you for the inquiry. We would like to inform you that the operating temperatures between CIE-M10 and CIE-M10A are different. The operating temperature for CIE-M10 is from 0 to 70 Celcius degree. For more details, you can refer to the datasheets below: +) CIE-M10 Data Sheet: https://www.eztcp.com/en/download/pds_files/ds_ciem10en.pdf +) CIE-M10A Data Sheet: https://www.eztcp.com/en/download/pds_files/ds_ciem10aen.pdf In your case, it is recommended to use CIE-M10A in such temperature conditions. We hope the above is helpful to you. Please feel free to leave us questions if you have any. Thank you very much. Best Regards > Philip Hortin wrote: > ------------------------------------ > Hi, Can you confirm the temperature range for the CIE-M10. The specifications states 0°C as the lowest operating temperature for the M10 but the M10A can go down to -40°C. I ask because I have a project the needs to operate down to -20°C in Antarctica and my local supplier has the M10 in stock. Can I use the M10 instead of the M10A. I only need 3 but If I have to use the M10A I will have to buy 10 minimum to get them from my local supplier. Thanks, Phil |
Writer | Sollae Systems | Company | |
|
|||