No. 490 Re: Re: Re: BREAK with EZL 200-F 2009-03-31

Hello,

Your request(adding the RFC2217 Break signal handling) is now under consideration.

I think we can answer it positively.
After it finish, we'll inform you by e-mail.

> Meunier wrote:
> ~~~~~~~~~~~~~~~~~~~~~~~~~~~
> Hello,
> Can you add the rfc2217 BREAK level to the EZL-200F firmware ? I don't need the VSP driver update as I directly connect to EZL.
>
> Also the minimum speed on EZL seems to be 600baud, after speed selected is no reliable.
>
> Regards
>
> > Sollae Systems wrote:
> > ~~~~~~~~~~~~~~~~~~~~~~~~~~~
> > Hello,
> >
> > I’m afraid that the EZL-200F and ezVSP, which program allows PC makes virtual serial ports, do not support sending or receiving the break signal.
> > By the way, baud rates of EZL-200F could be changed lower than 1200bps by entering consol mode. You can connect to EZL-200F through the telnet with “telnet [xxx.xxx.xxx.xxx]” command, and then, check the message which is started with “msh>”. Please refer to the below sequences.
> >
> > 1. Connect to the EZL-200F with telnet command
> >
> > 2. Input “env ezl” command on the window
> >
> > 3. Input Enter key on your keyboard until you can show the [BAUD RATE] option and enter the rate what you want to.
> >
> > 4. Input Enter key again and again until “update eeprom…done” message shows up on your screen.
> > 5. EZL-200F may reboot automatically when you done this.
> >
> > 6. If you change any options or parameters of EZL-200F and save the values by ezConfig, which is a configuration tool, the baud rate you configured through telnet in console mode will be changed again.
> >
> > Have a nice day.
> > Best Regards,
> >
> >
> > > meunier wrote:
> > > ~~~~~~~~~~~~~~~~~~~~~~~~~~~
> > > Hello,
> > > I have a EZL 200F FW 1.3i + EZTCP 2.3B.
> > > I can't have any break on output (break character or break level).
> > > I use 200F in T2S mode and RS232 serial type. I have also activate TELCOM mode.
> > > In I have also activated Telnet mode (RFC2217) on EZTCP.
> > > I have analyse TCP traffic between my computer and 200F and I don't see any packet for BREAK action.
> > > I have try using telnet terminal BREAK or IP command without result.
> > > I have try RFC2217 TELCOM BREAKON/BREAKOFF command using custom telnet without success.
> > >
> > > Is there any way to send BREAK level or as fallback BREAK character with 200F ?
> > > Also is there way to get lower speed than 1200bps ?
> > >
> > > Regards
> > >
> > > Sylvain

Writer Sollae Systems Company