No. 493 | Re: Re: BREAK with EZL 200-F | 2009-04-03 | ||
---|---|---|---|---|
Thanks you. Sylvain > Sollae Systems wrote: > ~~~~~~~~~~~~~~~~~~~~~~~~~~~ > Hello, > > Your request(adding the RFC2217 Break signal handling) is now under consideration. > > I think we can answer it positively. > After it finish, we'll inform you by e-mail. > > > Meunier wrote: > > ~~~~~~~~~~~~~~~~~~~~~~~~~~~ > > Hello, > > Can you add the rfc2217 BREAK level to the EZL-200F firmware ? I don't need the VSP driver update as I directly connect to EZL. > > > > Also the minimum speed on EZL seems to be 600baud, after speed selected is no reliable. > > > > Regards > > > > > Sollae Systems wrote: > > > ~~~~~~~~~~~~~~~~~~~~~~~~~~~ > > > Hello, > > > > > > I’m afraid that the EZL-200F and ezVSP, which program allows PC makes virtual serial ports, do not support sending or receiving the break signal. > > > By the way, baud rates of EZL-200F could be changed lower than 1200bps by entering consol mode. You can connect to EZL-200F through the telnet with “telnet [xxx.xxx.xxx.xxx]” command, and then, check the message which is started with “msh>”. Please refer to the below sequences. > > > > > > 1. Connect to the EZL-200F with telnet command > > > > > > 2. Input “env ezl” command on the window > > > > > > 3. Input Enter key on your keyboard until you can show the [BAUD RATE] option and enter the rate what you want to. > > > > > > 4. Input Enter key again and again until “update eeprom…done” message shows up on your screen. > > > 5. EZL-200F may reboot automatically when you done this. > > > > > > 6. If you change any options or parameters of EZL-200F and save the values by ezConfig, which is a configuration tool, the baud rate you configured through telnet in console mode will be changed again. > > > > > > Have a nice day. > > > Best Regards, > > > > > > > > > > meunier wrote: > > > > ~~~~~~~~~~~~~~~~~~~~~~~~~~~ > > > > Hello, > > > > I have a EZL 200F FW 1.3i + EZTCP 2.3B. > > > > I can't have any break on output (break character or break level). > > > > I use 200F in T2S mode and RS232 serial type. I have also activate TELCOM mode. > > > > In I have also activated Telnet mode (RFC2217) on EZTCP. > > > > I have analyse TCP traffic between my computer and 200F and I don't see any packet for BREAK action. > > > > I have try using telnet terminal BREAK or IP command without result. > > > > I have try RFC2217 TELCOM BREAKON/BREAKOFF command using custom telnet without success. > > > > > > > > Is there any way to send BREAK level or as fallback BREAK character with 200F ? > > > > Also is there way to get lower speed than 1200bps ? > > > > > > > > Regards > > > > > > > > Sylvain |
Writer | Meunier | Company | |
|
|||