No. 561 Re: EZVSP 2010-06-24

Hi

As far as I understand, your circumstance likes the below figure.

1. Communication is failed with a virtual serial port.

2. Communication is succeeded without a virtual serial port

In the above case, you should check if the data from the PC to the EZL-70 on each case are the same because you used different source program in both environments.
Please compare the “data 1” in case 1 and “data A” in case 2.

It will be greatly helpful for supporting and solving your problem that you capture and send the packet to us with Wireshark which is a network packet analyzing program.
E-mail: support@eztcp.com

You can download the program on the below site for free.
Download

If you have further questions, please let me know.
Thanks



> nonde wrote:
> ~~~~~~~~~~~~~~~~~~~~~~~~~~~
> Hello
>
> I have used ezvsp 2.3b software for creating a virtual serial port
> with EZL 70 device working in client mode (COD2)
> COM8 port has been succesfully created
> When I open an RS232 application program I get the indication
> Port OPEN 9600 8 n1 but when i try to send a protocol command
> to the serial device I get no response
> However, the communication in the TCP server (the server in which
> EZL 70 is connected) is correct and I can see the serial messages
> from the RS232 device coming on the TCP server
> messages from TCP server to the serial device are properly transfered
> and the RS232 device responds correctly
>
> The problem is that I can not send transmitting message from the normal RS232
> control program to the serial device through the serial port
> It seems that the command is sent to unit ( is shown on the TCP server)
> but the RS232 device does not respond
>
> I would highly appreciate any help

Writer Sollae Systems Company