No. 644 Re: Failure in configuring CSW-H80 2012-01-25

Hello.
This is technical support team of Sollae Systems.

If there is no problem on the stored modification, ezManager display the appending message.

If you saw the message, but module still doesn’t change the parameters,
Send me the ezManager version or CSW-H80 firmware version, or capture file.
Have a nice day.
Thank you.


> Krampe wrote:
> ------------------------------------
> Hello,
> I have purchased a CSW-H80 module.
> Unfortunately it is not possible to get modified configuration parameters like IP-Address stored in the module.
>
> Reading of the parameters works without any problem (MAC-Address matches with the printed address on the module).
>
> Writing seems to be working, but in fact, it doesn't.
> After sending the configuration data (could be watched by scope), I was asked to reboot the system.
> But after rebooting and reading the configuration appears unchanged.
>
> regards
> W. Krampe

Attachment 20120125_storedmessage.png
Writer Sollae Systems Company