No. 670 Re: Re: Re: Re: Re: Re: CSE-M53sending any file across computer 2012-03-26

Do you have an evaluation board for CSE-M53?
I cannot identify the 15th leg you said.
CSE-M53 has 24pins (JP1-12pins and JP2-12pins).
The 6th pin of JP2 is UART TXD.
You can capture the signal with this pin and GND (4th, 7th pin of JP1)

For your information, ezManager offers checking the number of sent or received bytes by the [Status] button.
The explanation of each item is as follows:
1. sio_rx : The number of bytes which are received from UART
2. net_tx : The number of bytes which are sent to network(TCP/IP)
3. net_rx : The number of bytes which are received from network
4. sio_tx : The number of bytes which are sent to UART

In the above itmes, number 2 counts up by number 1 and number 4 counts up by number 3.



You can see all the flow of the data with it.


Here is another one.
If you set the hardware flow control (RTS/CTS), both RTS and CTS pins should be connected with its counterpart. If those are not, the data would not be transferred.

Thank you.


> Anonymous wrote:
> ------------------------------------
>
> Thank Your method really good for us , but i have a new problem again , i can
>
> search m53 by ezManager ,can config ,but i doing test transferred data from M53
>
> to M53 fails. Then I use oscilloscope try to captured Tx signal (leg 15th in M53
>
> compare with GND )
>
> ,It'ss really silence (without pulse signals) although LED status are still brighting.
>
> Why? In case, Is product broken?
>
> Thanks for help thoroughly.
>
>
> > Sollae Systems wrote:
> > ------------------------------------
> > To search CSE-M53, a network connection is required like a picture below.
> >
> >
> >
> > We will test the terminal program which you used if you send us the program by e-mail.
> >
> > In my opinion, it seems that the products what you have are not broken because you succeeded transfer some data in ASCII.
> > By the way, each LED indicates various status of CSE-M53, tough.
> >
> > Thanks, in advance.
> >
> >
> > > Anonymous wrote:
> > > ------------------------------------
> > > Thank you to answered.
> > >
> > > but i can'sst search CSE-M53 with ezManager. How i should to do? Can i will transfer data from other terminal program? Or not, Can i will config CSE-M53 without ezManager?
> > >
> > > Is possibly CSE-M53 out of order(be broken)?, although LED status (TCP connection,Link,3.3V status )are still brighting.
> > >
> > >
> > >
> > >
> > > > Sollae Systems wrote:
> > > > ------------------------------------
> > > > Hi.
> > > >
> > > > Which program do you use?
> > > >
> > > > I tested sending a word file (.docx) with some terminal programs (Teraterm and Realterm) but I could not find anything wrong. It worked fine.
> > > >
> > > > As you know, CSE-M53 just passes data from serial (UART) to network (TCP/IP) and vice versa. This module doesn'ssst care what the data type is.
> > > >
> > > > Could you please check sizes of the sent and received data below?
> > > > 1. Serial RX of M53#1(Sender)
> > > > 2. Network TX of M53#1
> > > > 3. Network RX of M53#2(Receiver)
> > > > 4. Serial TX of M53#2
> > > >
> > > > All of above sizes should be the same in normal.
> > > >
> > > > You can show them in the status window by clicking [Status] button of ezManager.
> > > >
> > > > If you take and send some screenshots by e-mail, it may be helpful to us.
> > > > E-mail: support@sollae.co.kr
> > > >
> > > > About the last question(router thing), I am sorry but I cannot understand what you mean.
> > > > Could you please explain it again in detail?
> > > > I am sorry for your inconvenience.
> > > >
> > > > Have a nice day.
> > > >
> > > >
> > > > > Anonymous wrote:
> > > > > ------------------------------------
> > > > >
> > > > >
> > > > > > Pongsathon wrote:
> > > > > > ------------------------------------
> > > > > > we want sending any file(such as .doc, .jpg, .png) across COM to COM using 2 CSE-M53. now, we had 2 CSE-M53 connect togather between 2 com in attract picture.
> > > > > >
> > > > > > we config IP CSE-M53 in same subnets then try sending ASCII alphabet&number in simple test, it'ssss work. we loading file form COM by LOAD button and sent that flie through ,same number sending but doesn'ssst work. why?
> > > > > >
> > > > > > If should we sending file is .bin .txt?
> > > > > > If we replace COM1 into router which is connected internet. What COM2 will connected internet too?
> > > > > > answer us,Please.

Writer Sollae Systems Company