한국어 English Chinese Russian
bannerbar

Q&A



Your information is protected by SSL.
No. 680 Re: Re: Re: EZL-50L data frames 2012-05-25

Hello.

I'm so sorry.

Unfortunately to download the firmware, EZL-50L must enter the ISP mode.

So you should open the pos to change the mode (using a jumper)

I'm sorry for your inconvenience.

Have a nice day.

Thank you.



> Mohamed Moustafa wrote:
> ------------------------------------
> Hello,
>
> My EZL is installed inside a POS, is there a way to download new firmware without open the POS and deassemble the board,
>
> best regards,
>
>
> > Sollae Systems wrote:
> > ------------------------------------
> > Hello.
> >
> > This is a technical team of Sollae Systems.
> >
> > Are you using the ATC mode?
> >
> > It had a bug in ver. 1.2B.
> >
> > So please download the latest firmware(1.2E).
> >
> > [Firmware Download]
> >
> > It will be sent in one packet.
> >
> > Have a nice day.
> >
> > Thank you.
> >
> >
> >
> > > Mohamed Moustafa wrote:
> > > ------------------------------------
> > > Dear Gentlemen,
> > >
> > > Iam using EZL-50L/200L/70 ver 1.2B,
> > >
> > > when i send 50 bytes to the EZL through UART with baudrate 115200,
> > >
> > > the received data is as following,
> > >
> > > First TCP packet -> 1 bytes
> > > Second TCP packet -> 49 bytes
> > >
> > > is there a way to send the 50 bytes in one packet,
> > >
> > > best regards,
> > > mohamed

Writer Sollae Systems Company