No. 88 Re: Re: i can 2006-03-30

Firstly, i want to thank you for your quick answer.

My problem is that i can connect the module EZL-300W Lite through an hypher terminal, but there is no data which 0are send or received by the module.
So i can do nothing.
regards.
axel
> Sollae Systems wrote:
> ~~~~~~~~~~~~~~~~~~~~~~~~~~~
> Your explanation is not clear, so I can't understand your situation.
>
> Is your system like below?:
> [PC(Hypher terminal)] -- ethernet(LAN) -- EZL-300W Lite -- RS232 -- Key pad system
>
> If the keypad system sends data to RS232 port but you can't see the message from hypher terminal, You should check as follows:
>
> 1. RS232 cable connection
> (2-RXD, 3-TXD, 5-GND (in terms of EZL-300WL))
>
> 2. Buadrate, data bit length, parity, stop bit.
>
> 3. You can see the total byte that EZL-300WL received and transmitted from or to the serial port by [Status] of ezConfig.
>
> 4. You should check the TCP connection when you try to communicate.
>
>
> > axel goubaux wrote:
> > ~~~~~~~~~~~~~~~~~~~~~~~~~~~
> > i've tried to communicate with eztcp 300wl module with an hypher terminal console then the good message is displayed but after that when i try to tape one command with my keypad but nothing is displayed in the hypher terminal! Can you help me please. Thank you
> >
> > Axel.

Writer Sollae Systems Company