Your information is protected by SSL.
No. 89 Re: Re: Re: i can 2006-03-31

Please let me know your network system like below:
[PC(Hypher terminal)] -- ethernet(LAN) -- EZL-300W Lite -- RS232 -- Key pad system


> Sollae Systems wrote:
> ~~~~~~~~~~~~~~~~~~~~~~~~~~~
> Firstly, i want to thank you for your quick answer.
>
> My problem is that i can connect the module EZL-300W Lite through an hypher terminal, but there is no data which 0are send or received by the module.
> So i can do nothing.
> regards.
> axel
> > Sollae Systems wrote:
> > ~~~~~~~~~~~~~~~~~~~~~~~~~~~
> > Your explanation is not clear, so I can't understand your situation.
> >
> > Is your system like below?:
> > [PC(Hypher terminal)] -- ethernet(LAN) -- EZL-300W Lite -- RS232 -- Key pad system
> >
> > If the keypad system sends data to RS232 port but you can't see the message from hypher terminal, You should check as follows:
> >
> > 1. RS232 cable connection
> > (2-RXD, 3-TXD, 5-GND (in terms of EZL-300WL))
> >
> > 2. Buadrate, data bit length, parity, stop bit.
> >
> > 3. You can see the total byte that EZL-300WL received and transmitted from or to the serial port by [Status] of ezConfig.
> >
> > 4. You should check the TCP connection when you try to communicate.
> >
> >
> > > axel goubaux wrote:
> > > ~~~~~~~~~~~~~~~~~~~~~~~~~~~
> > > i've tried to communicate with eztcp 300wl module with an hypher terminal console then the good message is displayed but after that when i try to tape one command with my keypad but nothing is displayed in the hypher terminal! Can you help me please. Thank you
> > >
> > > Axel.

Writer Sollae Systems Company