Category : how to
As a RS485 network if you wish to send data to multiple systems at the same time, try to use UDP with broadcast IP address.
ezTCP supports the UDP communication mode.
In the case of EZL-50 and EZL-60, download UDP(U2S) firmware using HotFlash, and in the other products, set UDP(U2S) with a setup program such as ezConfig.
Since broadcast IP differs depending on the network environment,
make inquiry through the question-and-answer bulletin board.
(Your question should include local IP, subnet mask and gateway IP.)
The following is a setting example.
Setting example
ezTCP Mode |
UDP |
Local IP Address |
192.168.0.200 |
Subnet Mask |
255.255.255.0 |
Gateway IP Address |
192.168.0.1 |
Peer IP Address |
192.168.0.255 (broadcast IP) |
Local Port |
1470 |
Interval(10ms) |
0 |
Block(Byte) |
0 |
Peer Port |
1470 |
[PC #1]
Local IP Address |
192.168.0.2 |
Subnet Mask |
255.255.255.0 |
Gateway IP Address |
192.168.0.1 |
Local Port |
1470 |
[PC #2]
Local IP Address |
192.168.0.3 |
Subnet Mask |
255.255.255.0 |
Gateway IP Address |
192.168.0.1 |
Local Port |
1470 |
[PC #3]
Local IP Address |
192.168.0.4 |
Subnet Mask |
255.255.255.0 |
Gateway IP Address |
192.168.0.1 |
Local Port |
1470 |
See also
Related Products
[ Ethernet-Module ] CSE-M53, CSE-M32, EZL-50L, EZL-50M, EZL-410
[ Ethernet-Module with RJ45 ] CSE-M73, EZL-70
[ Ethernet-Board ] EZL-60L, EZL-60M, CSE-B63
[ Ethernet-External ] CSE-H55, CSE-H53, CSE-H25, CSE-H20, CSE-H21, EZL-200L, EZL-200F, EZL-400S
[ Wireless-External ] EZL-300S, CSW-H80
[ Wireless-Module ] CSW-M85, CSW-M83
[ PPP ] EZP-250, EZU-100, CSP-H50, EZP-EVB, EZU-EVB
[ I/O ] CIE-H10, CIE-M10